Installation and debugging of steel wire rope electric hoist

The rail frame used for the mobile hoist of the power supply is selected and automatically designed by the user according to the GB706-88 standard. When installing the trolley, use adjusting washers to adjust to ensure a 3~5mm gap between the wheel flange and the track edge.

The installation of the fixed electric hoist should ensure that the safety method is correct, and the support frame is safe and reliable.

For electric hoist electrical installation, please refer to the “wire rope electric hoist related circuit diagram” to install the electrical appliances.

The adjustment of the fire stopper is realized by adjusting the two striker blocks on the limit rod. The adjustment method is to loosen the screws on the striker block, and the striker blocks are placed on both sides of the rope guide card board. The card board can Push the bumper to move freely. Start the motor and start to lift, the clamp plate pushes the upper limit striker to move, and when the upper edge of the hook pulley shell is 150mm~50mm below the drum shell, stop rising, move the lower button, and when the rope guide moves back about 10mm Stop moving the upper limit striker close to the card board and tighten the bolts.